Unlikely to integrate
Information regarding this device is unconfirmed due to limited interactions with it. Support cannot guarantee integration.
Highlighted Comment Click the yellow highlighted text to read more
Implementations specific note
Important note
If a device is not on this list, it is unlikely to integrate
IO - Intraoral x-ray
XC - External Camera
Usually an intraoral camera like is shown below - video stream shows, but you capture still images. Intraoral camera is a wand with a capture button on the device to take an image. Video capture is not standard nor supported.
XC Modality can also represent something like photos from a camera in an Orthodontic context. It is standard to have a 9-tile Ortho layout that consists of full camera photos - patient photos, upper/lower arches, and bites.
CT - CBCBT/3D (what most people refer to as 3D in imaging)
PX - Panoramic
DX - Cephalometric
STL - Impressions / Intraoral scanners (3D)
Make |
Model |
Apteryx Online Capture |
XVC/DCV 3.5 |
Modalities |
Apteryx Online Capture Dependencies |
More Info |
|---|---|---|---|---|---|---|
AI-Dental |
DBS |
CCB TWAIN fails to return consistently. (Woodpecker Rebrand) Legacy TWAIN also unreliable. |
||||
PSPix Scanner |
IO |
|||||
PSPix 2 Scanner |
IO |
|||||
Sopix 2 Sensor |
IO |
|||||
All Pan/Ceph/CBCT Units |
PX, CT, DX |
Known Units: X-Mind Prime, X-Mind Trium PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
||||
Air Techniques |
ScanX Scanner VistaEasy Drivers |
IO, PX |
Possibly compatible via TWAIN, but should only be tried if upgrading to VisionX drivers and using Apteryx Online Capture’s direct plugin is not an option.(see below entry) |
Also may integrate via TWAIN. Recommend offices utilize newest VistaEasy drivers. Ensure offices have VistaEasy as a startup item on each acquisition PC |
||
Air Techniques |
ScanX Scanner VisionX Drivers (released ~9/2023) |
IO, PX |
VisionX Drivers must be installed. If the customer has VistaEasy or VistaScan drivers, install the Apteryx Online Capture Air Techniques plugin and refer them to Air Techniques to have their driver set upgraded to VisionX drivers. |
Only compatible with Apteryx Online Capture and the Air Techniques Plugin currently. Legacy TWAIN Fails to return images consistently CCB TWAIN in XVCapture returns blank images |
||
Air Techniques |
SensorX VisionX Drivers (VisionX 3.0.32) |
IO |
Legacy TWAIN - many extra clicks CCB TWAIN works, but must be version on 2.1.0 Requires VisionX Connect to be enabled on the unit within VisionX |
|||
Air Techniques |
ProVecta 3D Prime 2D/3D panoramic unit VisionX Drivers (VisionX 3.0.32) |
PX, CT |
Legacy TWAIN - 2D Only 3D - CT Importer Only Requires VisionX Connect to be enabled on the unit within VisionX |
|||
Azdent |
XVS2530 RVG Sensor |
IO |
Legacy TWAIN only - many extra clicks CCB TWAIN fails to return. Appears to be a woodpecker rebrand |
|||
Belmont |
BelSensor Gold Sensor |
IO |
||||
Belmont |
All Panoramic Units |
PX |
Legacy TWAIN only - a couple extra clicks |
|||
Duray Sensor |
IO |
Legacy TWAIN only - many extra clicks CCB TWAIN fails to return multiple images using progression |
||||
RVG 5100 |
IO |
|||||
RVG 5200 |
IO |
|||||
RVG 6100 |
IO |
|||||
RVG 6200 |
IO |
|||||
RVG 6500 |
IO |
|||||
CS 1500 Camera |
IO |
|||||
CS 3800 3D IO Scanner |
STL |
IO Scanners that produce 3D models are not supported/integrated See More |
||||
CS 7600 Scanner |
Legacy TWAIN also fails to return |
|||||
CS 8000 Unit |
PX |
Historic tickets show successful integration with Apteryx PX modality. Sunset by Carestream. Will not work on Windows 8 or newer. |
||||
8100 Unit |
PX, CT, DX |
|||||
8100 EVO Unit |
PX, CT, DX |
PX Direct Integration returning extra corrupt image with pano. Minor annoyance. Legacy TWAIN integration likely - a couple extra clicks CT Export/Import only - many extra clicks See More DX Direct integration likely, but not tested Legacy TWAIN integration likely - a couple extra clicks |
||||
8200 Unit |
PX, CT, DX |
PX Direct Integration returning extra corrupt image with pano. Minor annoyance. Legacy TWAIN integration likely - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
||||
9000 Unit |
PX |
|||||
9300 Unit |
PX, CT, DX |
Standard drivers for unit, Carestream plugin |
||||
9600 Unit |
PX, CT, DX |
PX Direct Integration eturning extra corrupt image with pano. Minor annoyance. Legacy TWAIN integration likely - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
||||
Daryou |
DY-50 |
XC |
||||
Woodpecker i-sensor |
IO |
Legacy TWAIN also unreliable. CCB TWAIN fails to return consistently. |
||||
DTX |
IO |
|||||
Dentalmind II |
IO |
|||||
Dentalmind III |
IO |
|||||
Anturi |
IO |
|||||
DentiMax Dream |
IO |
|||||
DentiMax4 |
IO |
|||||
DentiMax3 |
IO |
|||||
DirectUSB |
IO |
|||||
Open |
IO |
GxPicture with Dexis plugin |
This sensor appears to be E2v, but is consistently setup by Dentimax using GxPicture. Installers have confirmed that the sensor works in XVC and Apteryx Online Capture using the Dexis extension/plugin as long as GxPicture is set up as well. |
|||
Platinum Sensor |
IO |
|||||
Titanium Sensor |
IO |
|||||
DEXcam 3 (GXC-300) |
IO |
Capture button unsupported - requires user to click/hit spacebar |
||||
DEXcam 4 (GXC-400) |
IO |
|||||
FS Ergo |
IO |
Does not integrate, and TWAIN does not exist |
||||
IXS |
IO |
|||||
Digidoc |
Blu |
IO |
Legacy TWAIN only - many extra clicks CCB TWAIN fails to return consistently. |
|||
Edlen Imaging* |
EI Sensor |
IO |
||||
Edlen Imaging* |
Gemini-JP |
IO |
||||
FTG Imaging |
DC Air |
IO |
Inconsistent returns & crashing via TWAIN/CCB/Apteryx Online Capture |
|||
GXS-700 |
IO |
|||||
GXC-300 |
IO |
|||||
GXC-400 |
IO |
|||||
Denoptix |
IO, PX |
PX does not return |
||||
All Pan/Ceph/CBCT Units |
PX, DX |
Known Units: GXDP-700, GXDP-300 Gendex only supports PX/DX modalities. CT is not offered by Gendex. |
||||
Genoray |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
|||
iCat |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
|||
IXS Sensor |
IO |
|||||
Optime |
IO |
|||||
Snapshot |
IO |
|||||
All Pan/Ceph Units |
PX, CT, DX |
PX Direct Capture Supported via Instrumentarium extension, TWAIN fallback (Instrumentarium OP3D - legacy TWAIN only) CT Export/Import only - many extra clicks See More DX Direct Capture Supported via Instrumentarium extension, TWAIN fallback |
||||
ImageWorks/AFT |
EVA Sensor |
IO |
||||
EVA Select Sensor |
IO |
|||||
Solo |
IO |
|||||
Apex |
IO |
|||||
Progeny2/ClearVision |
IO |
|||||
Mouthwatch |
All XC Cameras |
XC |
||||
MyRay |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
|||
MyRay |
MyRay Sensor |
IO |
||||
Owandy Sensor |
IO |
|||||
Polaroid Sensor |
IO |
|||||
Villa Sensor |
IO |
|||||
All Pan/Ceph/CBCT Units |
PX, CT, DX |
CT Export/Import only - many extra clicks See More |
||||
Krystal-X Sensor |
IO |
|||||
Panoramic corporation (Pancorp) |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
|||
Panoura |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
|||
ProSensor |
IO |
|||||
Promax |
PX, CT, DX |
|||||
Viso |
PX, CT, DX |
PX No direct integration. XVCapture fails to return TWAIN. CT Export/Import only - many extra clicks See More DX No direct integration. XVCapture fails to return TWAIN. |
||||
KerenHD |
IO |
|||||
|
Prexion |
Evolve |
IO |
Unable to return images to Apteryx Online Capture Unable to return images to CCB TWAIN (XVC) Legacy TWAIN integration only (no progression capture) |
|||
Prexion |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
|||
PD740, PD750, PD760, and PD720 |
XC |
How ProDENT Intraoral Camera capture button work with Apteryx |
Capture button software needed for Apteryx Online Capture. Recommended for XVCapture as well, but should not be required. |
|||
Rayscan |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
CT Export/Import only - many extra clicks See More. PX/DX working through direct extension, CT working most times |
|||
Rayscan |
Rio Sensor |
IO |
||||
33 Sensor |
IO |
The IOSS MUST be installed for the device to work with Apteryx Online Capture. |
||||
Elite Sensor |
IO |
The IOSS MUST be installed for the device to work with Apteryx Online Capture. |
||||
CDR Sensor |
IO |
The IOSS MUST be installed for the device to work with Apteryx Online Capture. |
||||
Xios Sensor |
IO |
|||||
Xios Plus Sensor |
IO |
|||||
Xios XG Supreme |
IO |
|||||
All Pan/Ceph/CBCT Units |
PX, CT, DX |
Use XG extension for XG units, Sidexis4 extension for non XG units. XG units using driver version 2.63 or higher may not work in XVC. (downgrading to older drivers may allow it to work) PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
||||
BioRay HR |
IO |
|||||
BioRay SDX |
IO |
|||||
BioRay DuraSoft SDX |
IO |
|||||
BioRay IO Camera |
IO |
|||||
SigmaCR, |
IO |
|||||
Medallion |
IO |
|||||
Clio (e2vII) |
IO |
|||||
Clio Prime |
IO |
Legacy TWAIN only - many extra clicks CCB TWAIN fails to return consistently. |
||||
Suni* |
Lightyear (Suni USB) |
IO |
Integration is likely, but not guaranteed. Hardware troubleshooting is no longer supported. |
|||
Suni* |
Suni 2000 |
IO |
Integration is likely, but not guaranteed. Hardware troubleshooting is no longer supported. |
|||
Suni* |
Suni USBII |
IO |
Integration is likely, but not guaranteed. Hardware troubleshooting is no longer supported. |
|||
Suni* |
Suni IQ |
IO |
Integration is likely, but not guaranteed. Hardware troubleshooting is no longer supported. |
|||
Suni* |
All Pan/Ceph/CBCT Units |
PX, CT, DX |
PX Legacy TWAIN only - a couple extra clicks CT Export/Import only - many extra clicks See More DX Legacy TWAIN only - a couple extra clicks |
|||
Tuxedo Imaging |
Tuxedo Sensor |
IO |
||||
Tuxedo A Series Sensor |
IO |
|||||
TuxDeluxe B Series |
IO |
Also known as Promantix Sensors |
||||
EzSensor HD |
IO |
|||||
EzSensor P |
IO |
|||||
EzSensor Multi |
IO |
|||||
All Pan/Ceph/CBCT Units |
Pan/Ceph (PX, DX): 3D (CT): |
PX, CT, DX |
For XVCapture: CT Unlikely to integrate: Green X, Green X12 Green X12 model units are unable to return 2D images via Vatech extension - TWAIN must be used Likely to integrate at with lower FOVs (driver version must NOT be 1.1.0.0 – Vatech will need to help find driver version): PaX-i3D Smart, Smart Plus, PaX-i3D Green For Apteryx Online Capture: Vatech pan/ceph (2D acquisition) utilizes the TWAIN plugin Vatech CTs (3D acquisition) utilizes the Vatech plugin The version of the drivers can be checked by IT on the CBCT capture computer on C:\VCaptureSW\EXE\VCaptureSW.exe Right click > Properties > Details Tab. Document “File Version”.
IS(V.1.1.0.1 BN0005)_In_SW(V1.1.0.1 BN0004), IS(V.1.1.0.0 BN1012)_In_SW(V1.1.0.0 BN1006), |
|||
QuickRay DirectUSB |
IO |
|||||
QuickRay HD |
IO |
|||||
UniRay (Vatech) |
IO |
|||||
QuickRayDX |
Limited exposure to sensor. Should work with TWAIN/CCB |
|||||
XDR |
IO |
Intermittent threshold issues in Apteryx Online Capture |
||||
Clarity |
IO |
TWAIN plugin, ensure “C” option is selected in TWAIN interface when capture popup shows |
TWAIN only (TWAIN plugin, CCB TWAIN) Intermittent threshold issues in Apteryx Online Capture |